NATURAL PRODUCT RESEARCH AND DEVELOPMENT ›› 2017, Vol. 29 ›› Issue (11): 1841-1845. doi: 10.16333/j.1001-6880.2017.11.005

• Article • Previous Articles     Next Articles

Determination of Three Phenylethanoid Glycosides in Intracerebral Dialysate by LC-MS/MS and Comparison of in vivo and in vitro Recovery of Microdialysis Probe

XIA Yu-ying,CHEN Ling,LIU Fang-le,ZHU Chen-chen,LIN Chao-zhan*   

  1. Institute of Clinical Pharmacology,Guangzhou University of Chinese Medicine,Guangzhou 510405,China
  • Online:2017-11-29 Published:2017-11-30

Abstract: To establish a method for detecting micro-dialysis recovery of forsythoside B,acteoside and isoacteoside,measuring the concentration of three phenylethanoid glycosides in intracerebral dialysate by LC-MS/MS method,and compare the probe recovery in vivo and in vitro.The recovery of three phenylethanoid glycosides was 19.5%,27.5%,31.9% in vitro and11.6%,16.0%,16.9% in vivo.The probe recovery of three phenylethanoid glycosides in vivo is lower than in vitro,and both are stable in different concentrations.The LC-MS/MS method is accurate,sensitive,and reproducible for quantitative determination of three phenylethanoid glycosides in microdialysate.

Key words: microdialysis, in Vivo and in Vitro Recovery, phenylethanoid glycosides, LC-MS/MS

CLC Number: